Description
A wedge for installations that cannot be cooled down. It withstands 260°C, so a pipeline, vessel or boiler is inspected while running, with no shutdown and no waiting for it to cool. The contact time per placement comes from the procedure — the wedge takes the heat rather than holding it off indefinitely.
Features
- Rated to 260°C
- 55° refraction, shear wave
- Water feed and scanner yoke mounting points
- DP28 housing, 64 × 44 × 34 mm
Technical data
| Model | SDP28-N55S-IH(HT) |
| Probe housing | DP28 |
| Operating temperature | up to 260°C |
| Refraction angle | 55° |
| Wave mode | shear |
| Length L | 64 mm |
| Width W | 44 mm |
| Height H | 34 mm |
| Wedge angle | 39.5° |
| Wedge velocity | 2525 m/s |
The (HT) suffix marks the high temperature version. Above that range the job calls for delay line probes, which we list separately.
Technical data after the manufacturer catalogue, Doppler Electronic Technology (2026). X-TEST — exclusive distributor for Poland, Lithuania, Latvia and Estonia.